Backup/Restoration using SST
■ Overview
Connect the PC in which SST is installed to the machine which has been started in download mode via a network cable, and
back up/restore the data in the machine.
PC for service
PC for service
iR Device
iR Device
HDD
HDD
Flash PCB
Flash PCB
SramImg.bin
SramImg.bin
MeapBack.bin
MeapBack.bin
SST
SST
iR ----
iR ----
System
System
MeapBackup.bin
MeapBackup.bin
Main Controller PCB
Upload/Download
(Backup/Restore)
Upload/Download
(Backup/Restore)
Data in MEAP area
Backup data
Downloaded/Uploaded file names
Backup data RAM
SramImg.bin(to be uploaded / downloaded)
Data in MEAP area
MeapBack.bin(to be uploaded / downloaded)
For investigation in Dev
Sublog.bin((Uploadable))
Service Print
The text file of the contents which You output to paper with a service mode(Uploadable).
• SramImg.bin can be backed up with SST but only to the hard disk of the PC.
• MeapBack is the MEAP application and its data stored in the MEAP area of the hard disk.
Data that can be backed up in service mode
Backup data
Service mode
Backup of Reader Controller PCB
COPIER > FUNCTION > SYSTEM > RSRAMBUP (Backup)
COPIER > FUNCTION > SYSTEM > RSRAMRES (Restore)
Backup of DC Controller PCB
COPIER > FUNCTION > SYSTEM > DSRAMBUP (Backup)
COPIER > FUNCTION > SYSTEM > DSRAMRES (Restore)
Data is stored in Flash ROM.
● Settings
Enter download mode to back up/restore the machine using SST. The following IP address is automatically assigned to the
machine when it enters download mode.
• IP address:172.16.1.100
• Subnet mask:255.255.255.0
In order to connect the PC to the machine, change the network address of the PC in which SST is installed as indicated below.
• IP address:172.16.1.xxx (except 172.16.1.100)
• Subnet mask:255.255.255.0
• Default gateway: arbitrary
CAUTION:
Disconnect USB memory storage device storage devices if connected.
Communication to SST is disabled in this machine if any USB memory storage device storage device is recognized. SST
and the USB memory storage device storage device cannot be used concurrently.
If the PC has the connection to the network, the settings changed to the above-mentioned may cause network failures due
to redundant IP addresses, etc. Ensure that the PC is disconnected from the network when you change the PC network
settings. Alternatively use the cross cable to connect the PC to this machine.
6. Troubleshooting
496
Summary of Contents for imageRUNNER ADVANCE C3330 Series
Page 1: ...Revision 7 0 imageRUNNER ADVANCE C3330 C3325 C3320 Series Service Manual ...
Page 18: ...Product Overview 1 Product Lineup 7 Features 11 Specifications 17 Parts Name 26 ...
Page 518: ...Error Jam Alarm 7 Overview 507 Error Code 511 Jam Code 617 Alarm Code 624 ...
Page 1020: ...9 Installation 1008 ...
Page 1022: ...2 Perform steps 3 to 5 in each cassette 9 Installation 1010 ...
Page 1024: ...5 6 Checking the Contents Cassette Feeding Unit 1x 3x 2x 1x 9 Installation 1012 ...
Page 1027: ...3 4 NOTE The removed cover will be used in step 6 5 2x 2x 9 Installation 1015 ...
Page 1046: ...When the Kit Is Not Used 1 2 Close the Cassette 2 When the Kit Is Used 1 9 Installation 1034 ...
Page 1068: ... Removing the Covers 1 2x 2 1x 9 Installation 1056 ...
Page 1070: ...3 1x 1x 9 Installation 1058 ...
Page 1083: ...6 7 TP M4x8 2x 2x 9 Installation 1071 ...
Page 1084: ...When Installing the USB Keyboard 1 Cap Cover Wire Saddle 9 Installation 1072 ...
Page 1129: ...9 2x 10 2x 11 9 Installation 1117 ...
Page 1135: ...Remove the covers 1 ws 2x 2 1x 9 Installation 1123 ...
Page 1140: ...2 2x 3 Connect the power plug to the outlet 4 Turn ON the power switch 9 Installation 1128 ...
Page 1176: ... A 2x Installing the Covers 1 1x 2 2x 9 Installation 1164 ...
Page 1190: ...14 Install the Cable Guide to the HDD Frame 4 Hooks 1 Boss 9 Installation 1178 ...