COPIER (Service mode for copier) > DISPLAY (State display mode) > DENS
P-D-P-C
2
Dspl front side (C/Bk) drk crrnt (Pwave)
Detail
To display the C/Bk-color dark current (P-wave) detected by the Registration Patch Sensor Unit
(Front).
At low density or fogging deterioration, use this item to check whether there is a problem in the
Registration Patch Sensor Unit (Front).
Use Case
At low density or fogging deterioration
Display/Adj/Set Range
0 to 1023
Appropriate Target Value
10 - 100
P-B-P-Y
2
Dspl ITB rear side base intnsty (Pwave)
Detail
To display the ITB background light intensity (P-wave) detected by the Registration Patch Sensor
Unit (Rear).
At low density or fogging deterioration, use this item to check whether there is a problem in the
Registration Patch Sensor Unit (Rear).
Use Case
At low density or fogging deterioration
Display/Adj/Set Range
0 to 1023
Appropriate Target Value
300 - 900
P-B-P-C
2
Dspl ITB front side base intnsty (Pwave)
Detail
To display the ITB background light intensity (P-wave) detected by the Registration Patch Sensor
Unit (Front).
At low density or fogging deterioration, use this item to check whether there is a problem in the
Registration Patch Sensor Unit (Front).
Use Case
At low density or fogging deterioration
Display/Adj/Set Range
0 to 1023
Appropriate Target Value
300 - 900
P-B-S-Y
2
Dspl ITB rear side base intnsty (Swave)
Detail
To display the ITB background light intensity (S-wave) detected by the Registration Patch Sensor
Unit (Rear).
At low density or fogging deterioration, use this item to check whether there is a problem in the
Registration Patch Sensor Unit (Rear).
Use Case
At low density or fogging deterioration
Display/Adj/Set Range
0 to 1023
Appropriate Target Value
10 - 300
P-B-S-C
2
Dspl ITB front side base intnsty (Swave)
Detail
To display the ITB background light intensity (S-wave) detected by the Registration Patch Sensor
Unit (Front).
At low density or fogging deterioration, use this item to check whether there is a problem in the
Registration Patch Sensor Unit (Front).
Use Case
At low density or fogging deterioration
Display/Adj/Set Range
0 to 1023
Appropriate Target Value
10 - 300
P-D-S-Y
2
Dspl rear side (Y/M) drk crrnt (Swave)
Detail
To display the Y/M-color dark current (S-wave) detected by the Registration Patch Sensor Unit
(Rear).
At low density or fogging deterioration, use this item to check whether there is a problem in the
Registration Patch Sensor Unit (Rear).
Use Case
At low density or fogging deterioration
Display/Adj/Set Range
0 to 1023
Appropriate Target Value
10 - 100
8. Service Mode
701
Summary of Contents for imageRUNNER ADVANCE C3330 Series
Page 1: ...Revision 7 0 imageRUNNER ADVANCE C3330 C3325 C3320 Series Service Manual ...
Page 18: ...Product Overview 1 Product Lineup 7 Features 11 Specifications 17 Parts Name 26 ...
Page 518: ...Error Jam Alarm 7 Overview 507 Error Code 511 Jam Code 617 Alarm Code 624 ...
Page 1020: ...9 Installation 1008 ...
Page 1022: ...2 Perform steps 3 to 5 in each cassette 9 Installation 1010 ...
Page 1024: ...5 6 Checking the Contents Cassette Feeding Unit 1x 3x 2x 1x 9 Installation 1012 ...
Page 1027: ...3 4 NOTE The removed cover will be used in step 6 5 2x 2x 9 Installation 1015 ...
Page 1046: ...When the Kit Is Not Used 1 2 Close the Cassette 2 When the Kit Is Used 1 9 Installation 1034 ...
Page 1068: ... Removing the Covers 1 2x 2 1x 9 Installation 1056 ...
Page 1070: ...3 1x 1x 9 Installation 1058 ...
Page 1083: ...6 7 TP M4x8 2x 2x 9 Installation 1071 ...
Page 1084: ...When Installing the USB Keyboard 1 Cap Cover Wire Saddle 9 Installation 1072 ...
Page 1129: ...9 2x 10 2x 11 9 Installation 1117 ...
Page 1135: ...Remove the covers 1 ws 2x 2 1x 9 Installation 1123 ...
Page 1140: ...2 2x 3 Connect the power plug to the outlet 4 Turn ON the power switch 9 Installation 1128 ...
Page 1176: ... A 2x Installing the Covers 1 1x 2 2x 9 Installation 1164 ...
Page 1190: ...14 Install the Cable Guide to the HDD Frame 4 Hooks 1 Boss 9 Installation 1178 ...