Target idle rpm
NAVIGATOR: ELECTRICAL ERRORS
EEPROM Error P0601
- circuit not operational.
Error cause
•
Replace injection ECU. The instrument panel does not indicate the presence of this error
even in the ATT status.
RAM Error P0604 -
circuit not operational.
Error cause
•
Replace injection ECU. The instrument panel does not indicate the presence of this error
even in the ATT status.
ROM Error P0605 -
circuit not operational.
Error cause
•
Replace injection ECU. The instrument panel does not indicate the presence of this error
even in the ATT status.
A/D converter P0607-
circuit not operational.
Error cause
•
Replace injection ECU.
Level 2 safety reset P0608
Error cause
•
As the level 2 safety system (comparison between requested torque and calculated torque)
has detected a fault, the control unit has reset engine (C gravity).
Troubleshooting
•
Continue fault search for the other errors detected.
Safety Engine Stop P0609
Error cause
•
As the level 3 safety system (control EEPROM) has detected a fault, the control unit has
shut off the engine (D gravity).
Troubleshooting
•
Replace Marelli control unit.
Reset lines error P0610-
circuit not operational
Error cause
•
Problems on the reset lines (PINS 55 and 56 of the VEHICLE connector) of the throttle
motors: lines used to interrupt motor functioning for safety reasons.
Troubleshooting
Electrical system
DORSODURO FACTORY ABS