2.2 Troubleshooting with Error Messages
VJ1324E-M-02
2.2.3 Errors Requiring Reboot
P.2-23
4
E071 Err
PF Current
E073 Err
PF2 Current
An overload
condition is
detected in PF
motor (X-axis)
during printer
operation.
1.
Check error history from "Test7: Record" of self-
diagnosis function.
-
2. Set the number of endurance running cycles to 50 or
more from "Life2: PF motor" of self-diagnosis
function, and check if "PF motor Timeout" occurs.
Check the connection of following MAIN
board Assy connectors.
•
PF motor cable Assy connector
•
PF encoder Assy connector
Replace the power board Assy if it is
damaged.
3.
Check "Encoder: PF" from "Test5: Encoder" of self-
diagnosis function.
If NG, check the connection of MAIN board
Assy connector.
4. Check if MAIN Power Board normally supplies
DC24V.
Replace the power board Assy if it is
damaged.
5. PF motor Assy may be defective.
Replace PF motor Assy .
6. MAIN board Assy may be defective.
Replace MAIN board Assy .
No.
Message
Symptoms
Check Item
Action
Reference