3.3.3 Replacing Cover Switch Assy
、
Sensor Cover L Assy, Sensor Cover R Assy
P.3-28
3.3 Replacing Cover Peripherals
VJ1324E-M-02
5.
Remove the screws (3 pieces) retaining cover L fixing material B.
6.
While holding square nut placed on the behind of maintenance cover sensor Assy,
remove screws (2 pieces) retaining maintenance cover sensor Assy.
7.
Remove square nut and cover Switch Assy .
8.
Replace cover Switch Assy .
9.
To reassemble the unit, reverse the removal procedure.
NOTE
After replacing maintenance cover sensor Assy, make sure to adjust the
mounting position of maintenance cover sensor Assy.
"4.11 Cover Switch Sensor Assy Position Adjustment" p.4-20
No.
Name
1
Screws retaining cover L fixing material B
2
cover L fixing material B
No.
Name
1
Square nut
2
Cover Switch Assy
3
Pan-head screw with spring washer and flat washer M2
×
12
1
1
2
1
2
2
3