3.13.5 Replacing Take-Up Unit Control Board Assy
P.3-169
3.13 Replacing Take-Up Unit (Option)
VJ1324E-M-02
3.13.5 Replacing Take-Up Unit Control Board Assy
CAUTION
• When replacing take-up unit, unplug the AC inlet cable and leave it for a while
before operation.
If operating while the AC inlet is still plugged in, it may damage the board or may
give an electrical shock to the operator.
• When handling board, do not touch the elements on the board with bare hands.
The elements may be damaged by static electricity.
(1) Removing Board Chassis
1.
Remove take-up scroller.
2.
Remove tension arm.
"3.13.1 Removing Tension Arm" p.3-162
3.
Remove take-up unit.
"3.13.2 Removing Take-Up Unit" p.3-164
4.
Remove the screws (4 pieces) retaining board chassis on chassis (out).
5.
Remove take-up motor Assy cable, take-up ON sensor relay Assy, and take-up OFF sensor relay
Assy from the connector on take-up control board Assy that came out.
6.
Remove board chassis.
7.
To reassemble the unit, reverse the removal procedure.
No.
Name
1
Board chassis
2
Board chassis screw
(pan-head screw with spring washer and flat washer M3
×
6)
1
2
2
3
3
Chassis (out)
No.
Name
1
Take-up control board Assy
2
Cable of the take-up motor Assy
3
Take-up ON sensor relay Assy , Take-up OFF sensor relay
Assy .
1
2
3
Summary of Contents for ValueJet VJ-1324
Page 1: ...VJ1324E M 02 VJ 1324 Full Color Inkjet Printer MAINTENANCE MANUAL ...
Page 86: ...P 3 4 VJ1324E M 02 3 13 7 Replacing Peripheral Devices of VJ Take Up Unit Motor Assy 3 179 ...
Page 409: ...P 10 1 VJ1324E M 02 10 Appendix 10 1 Introduction 10 2 10 2 Maintenance Part List 10 2 ...