4.5.1 Adjustment Procedure
P.4-8
4.5 PF Encoder Assy Position Adjustment
VJ1324E-M-02
4.5 PF Encoder Assy Position Adjustment
This section describes the procedure to adjust the PF encoder assembly.
After replacing the PF encoder, adjust the PF encoder position.
4.5.1
Adjustment Procedure
To adjust PF encoder Assy, follow the steps below.
1.
Remove Side Cover L.
"3.2.3 Removing Side Cover L and Replacing Maintenance Cover Holder" p.3-11
2.
Loosen the screws retaining the PF encoder fixing plate.
3.
Align so that the PF encoder scale is placed in the gap of the PF encoder Assy, and
then tighten the screw.
NOTE
Align so that the PF encoder scale is placed in the gap of the PF encoder.
No.
Name
1
PF encoder Assy
2
PF encoder fixing plate screw
(round head spring screw M3
×
6: 1)
1
2
No.
Name
1
PF encoder Assy
2
PF encoder scale
1
2
PF encoder scale
PF encoder
Slit guide
Speed reduction pulley side