
2.2 Troubleshooting with Error Messages
VJ1324E-M-02
2.2.3 Errors Requiring Reboot
P.2-22
3
E069 Err
PF Timeout
An anomaly is
detected in media
feed amount (X-
axis) during
printer operation.
Displayed when
Grid roller has not
reached the
designated
position.
1. Check error history from "Test7: Record" of self-
diagnosis function.
-
2. Set the number of endurance running cycles to 50 or
more from "Life2: PF motor" of self-diagnosis
function, and check if "PF motor Timeout" occurs.
Check the connection of following MAIN
board Assy connectors.
•
PF motor cable Assy connector
•
PF encoder Assy connector
Replace the power board Assy if it is
damaged.
"5.5.4 Sensor Menu" p.5-12
"3.4.10 Replacing Power Board
3. Check "Encoder: PF" from "Test5: Encoder" of self-
diagnosis function.
If NG, check the connection of MAIN board
Assy connector.
4. Check if MAIN Power Board normally supplies
DC24V.
Replace the power board Assy if it is
damaged.
5. PF motor Assy may be defective.
Replace PF motor Assy .
6. MAIN board Assy may be defective.
Replace MAIN board Assy .
No.
Message
Symptoms
Check Item
Action
Reference
Summary of Contents for ValueJet VJ-1324
Page 1: ...VJ1324E M 02 VJ 1324 Full Color Inkjet Printer MAINTENANCE MANUAL ...
Page 86: ...P 3 4 VJ1324E M 02 3 13 7 Replacing Peripheral Devices of VJ Take Up Unit Motor Assy 3 179 ...
Page 409: ...P 10 1 VJ1324E M 02 10 Appendix 10 1 Introduction 10 2 10 2 Maintenance Part List 10 2 ...
Page 419: ......
Page 420: ......