4.9.2 Adjustment Procedure
P.4-20
4.11 Cover Switch Sensor Assy Position Adjustment
VJ1324E-M-02
4.11 Cover Switch Sensor Assy Position
Adjustment
Always adjust the mounting position of Cover Switch sensor Assy after replacing Cover
Switch sensor Assy.
1. Open maintenance cover.
2.
Loosen the screw above maintenance cover sensor assembly
3. Loosen screw below maintenance cover sensor assembly.
4. Secure assembly with the screw below maintenance cover sensor assembly as close
as to the front side.
5. Tighten the screw above maintenance cover sensor assembly.
Start up from self-diagnosis mode and check that “Closed” is displayed when
maintenance cover is closed from “Check: Test" - “Test: Sensor” - “Sensor:
Maintenance cover.”
No.
Name
1
Screw above Cover Switch Sensor Assy
2
Screw below Cover Switch Sensor Assy
1
2
Summary of Contents for ValueJet VJ-1324
Page 1: ...VJ1324E M 02 VJ 1324 Full Color Inkjet Printer MAINTENANCE MANUAL ...
Page 86: ...P 3 4 VJ1324E M 02 3 13 7 Replacing Peripheral Devices of VJ Take Up Unit Motor Assy 3 179 ...
Page 409: ...P 10 1 VJ1324E M 02 10 Appendix 10 1 Introduction 10 2 10 2 Maintenance Part List 10 2 ...
Page 419: ......
Page 420: ......