3.7.7 Replacing Solenoid Head Assy
P.3-112
3.7 Replacing Carriage Peripherals
VJ1324E-M-02
1.
Install Solenoid head cleaning jib on the new Solenoid head Assy.
Make sure that the filter (silver part) side of Solenoid head Assy is connected to the Solenoid head
cleaning jig 1 side.
2.
Attach the cleaning cartridge for the eco solvent inks to the top of the Solenoid head cleaning jig 1.
3.
Pull Pump of Syringe attached to Solenoid head cleaning jig 2 and inflow about 3cc of Cleaning
liquid into the cylinder of Syringe.
NOTE
Air should not be included in the 3cc. Make sure that there is 3cc of Cleaning liquid only
when pulling the pump of Injector.
4.
Turn Solenoid head Assy upside down to let Cleaning liquid settle in Solenoid head Assy.
CAUTION
• Do not hold the transparent films on the sides of Solenoid head Assy. Cleaning
liquid inside Solenoid head Assy inflows into the tube.
• Do not damage the transparent films on the sides of Solenoid head Assy.
5.
Remove the cleaning cartridge from the Solenoid head cleaning jig1.
6.
Remove the cleaning liquid from the Solenoid head Assy by pulling the syringe pump.
No.
Name
1
Solenoid head Assy
2
Solenoid head cleaning jig 1
3
Solenoid head cleaning jig 2
4
Filter
2
4
Connect Solenoid Head cleaning jig 1
1
3
Connect Solenoid Head cleaning jig 2
No.
Name
1
Cleaning liquid cartridge
2
Solenoid head cleaning jig 1
3
Syringe
2
3
1
Summary of Contents for ValueJet VJ-1324
Page 1: ...VJ1324E M 02 VJ 1324 Full Color Inkjet Printer MAINTENANCE MANUAL ...
Page 86: ...P 3 4 VJ1324E M 02 3 13 7 Replacing Peripheral Devices of VJ Take Up Unit Motor Assy 3 179 ...
Page 409: ...P 10 1 VJ1324E M 02 10 Appendix 10 1 Introduction 10 2 10 2 Maintenance Part List 10 2 ...
Page 419: ......