2.2 Troubleshooting with Error Messages
VJ1324E-M-02
2.2.3 Errors Requiring Reboot
P.2-28
10
E075 Err
Head cable
An anomaly is
detected in Pre
heater system
(Thermistor,
Heater).
Head FFC may be malfunctioning.
1.
Check the connection of head FFC.
2.
Replace head FFC.
3.
Replace print head.
11
E076 Err
Pre heat
An anomaly is
detected in Pre
heater system
(Thermistor,
Heater).
1.
Thermistor or Heater’s connector may be disconnected,
wiring may be faulty, or Thermistor cable maybe nipped by
plates, or Heater may be damaged.
1.
Check the connection of the communication
cable.
2.
Replace the communication cable.
3.
Replace Heater CONT board Assy.
“Operation Manual”
12
E076 Err
Plt. heat
An anomaly is
detected in Platen
heater system
(Thermistor,
Heater).
13
E078 Err
After Heat
An anomaly is
detected in After
heater system
(Thermistor,
Heater).
No.
Message
Symptoms
Check Item
Action
Reference