3.5.6 Replacing Heater Section
P.3-76
3.5 Replacement of PF Driving Section Components
VJ1324E-M-02
(2) Replacing Pre-Heater Section
(2-a)Replacing Pre Heater relay Assy
T I P
• Replacing Procedure For Maintenance Part:PRE_H relay Assy, PRE_H2 Relay Assy.
These parts will be referred to as Pre Heater relay Assy in this manual.
• The seal is stuck on the connector of the Pre Heater relay Assy.
• This section describes the procedure to replace PRE_H2 relay Assy.When replacing
PRE_H relay Assy(origin side) , refer to the procedure in this section.
1.
Remove Paper guide R2.
"3.2.7 Removing Paper Guide R2" p.3-17
2.
Remove the clamps (3 pieces) under the plate which the Pre Heater relay Assy is mounted.
NOTE
Remove the clamps (3 pieces) with clamping the cables.
3.
Remove the screws (2 pieces) retaining plate.
Connected to
(
Maintenance parts name
)
Seal
Origin side
(
PRE_H relay Assy
)
The opposite side of Origin
(
PRE_H2 relay Assy
)
24+
24
1
2
1
1
1
2
2
3
No.
Name
1
Plate
2
Clamp
3
Pre Heater relay Assy
No.
Name
1
plate
2
clamp
1
1
2
2
Summary of Contents for ValueJet VJ-1324
Page 1: ...VJ1324E M 02 VJ 1324 Full Color Inkjet Printer MAINTENANCE MANUAL ...
Page 86: ...P 3 4 VJ1324E M 02 3 13 7 Replacing Peripheral Devices of VJ Take Up Unit Motor Assy 3 179 ...
Page 409: ...P 10 1 VJ1324E M 02 10 Appendix 10 1 Introduction 10 2 10 2 Maintenance Part List 10 2 ...
Page 419: ......
Page 420: ......