2.2 Troubleshooting with Error Messages
VJ1324E-M-02
2.2.3 Errors Requiring Reboot
P.2-18
13
E 016 Overflow
[
12
]
Arithmetic
overflow
exception error:
Overflow is
detected.
1.
Check AC power supply and printer peripherals.
2.
Check whether the same error occurs.
Even when there is no
problem, turn off the printer and turn it back on a few times to
check.
3.
Check the serial number of the printer.
4.
MAIN board Assy may be damaged.
• Contact your local MUTOH dealer.
• Replace MAIN board Assy .
14
E 016 Trap
[
13
]
Arithmetic
overflow
exception error:
Overflow is
detected.
15
E 016 Floating
[
15
]
Floating decimal
point exception
error:
An anomaly is
detected in
floating decimal
point.
16
E 016 WatchDog
[
32
]
Watchdog time-
out exception
error:
A time-out is
detected in
Watchdog.
17
E 016 Abort Err
[
33
]
Abort error:
Abort is detected.
18
E016 Flash
Rom[35]
The content of
flash ROM may
be destroyed.
19
E016 Exception
Err [XX]
EXC error
(undefined) other
than the above has
occured.
XX stands for a
number.
No.
Message
Event/
symptom
Check item
Action
Reference