3.7.6 Replacing Print Head
P.3-107
3.7 Replacing Carriage Peripherals
VJ1324E-M-02
8.
Raise the notch of Head adjustment cam to the top.
9.
Turn Connector Solenoid Heads (8 pieces) 45 degrees (clockwise), release the lock, and pull it
out.
CAUTION
Turning it anticlockwise will loosen the joint, resulting in ink leakage.
10. Remove screws (4 pieces) retaining Head base.
11. Remove Print head from Head mounting plate.
12. Pull out Head FFCs (4 pieces) from Print head.
No.
Name
1
Notch of Head adjustment cam
No.
Name
1
Connector Solenoid head
1
1
No.
Name
1
Pan-head screw with spring washer and flat washerM3
×
6
2
Head base
3
Head mounting plate
No.
Name
1
Head FFC
1
1
2
2
3
1