3.8.1 Replacing Maintenance Assy
P.3-138
3.8 Replacing Maintenance Section
VJ1324E-M-02
3.8
Replacing Maintenance Section
3.8.1
Replacing Maintenance Assy
NOTE
When replacing maintenance Assy, make sure to clear the following counter.
。
•
「
Cleaning
」 :
"6.3.2 Counter Initialization Menu" p.6-11
1.
Remove I/H Cover.
"3.2.1 Removing I/H Cover" p.3-7
2.
Remove Side Cover R.
"3.2.2 Remove Side Cover R" p.3-8
3.
Open Front Cover.
4.
Push up pressure lever in the direction of the red arrow.
5.
Move the Carriage to the opposite side of origin.
"3.7.1 How To Release Carriage Lock" p.3-98
6. Remove the connector of wiper origin sensor relay Assy from wiper origin sensor.
7.
Remove the connector of wiper origin sensor relay Assy from the clamp.
8.
Remove the connector of pump motor relay Assy.
No.
Name
1
Front Cover
2
Pressure Lever
1
2
No.
Name
1
Connector of wiper origin sensor relay Assy
2
Wiper origin sensor
3
Clamp
4
Connector of pump motor relay Assy
5
Pump motor relay Assy
5
$CEMUKFGQH/CKPVGPCPEG5GEVKQP
1
3
4
2