3.5.1 Replace PF Motor Assy
P.3-61
3.5 Replacement of PF Driving Section Components
VJ1324E-M-02
3.5 Replacement of PF Driving Section
Components
3.5.1
Replace PF Motor Assy
1.
Initialize PF Motor counter.
"6.3.2 Counter Initialization Menu" p.6-11
2.
Remove Side Cover L.
"3.2.3 Removing Side Cover L and Replacing Maintenance Cover Holder" p.3-11
3.
Remove the cable of PF Motor Assy from PF Motor Relay Assy.
4.
Loosen the screws (2 pieces) retaining PF motor Assy on PF bracket, then remove
PF speed reduction belt from PF motor
Assy.
No.
Name
1
Cable of PF Motor Assy
2
PF Motor Relay Assy
1
2
No.
Name
1
PF bracket
2
Pan-head screw with spring washer and flat washerM4
×
8
3
PF speed reduction belt
1
2
3
Summary of Contents for ValueJet VJ-1324