Pre-Manual Switchover Switch Integrity Diagnostic Utility
Switchover Impact Alarms Check
The Cisco BTS 10200 Softswitch Pre-Manual Switchover Switch Integrity Diagnostic Utility feature
queries the database for the following alarms to see if they are being raised by the switchover target side.
A complete listing of these outstanding alarms is stored in a log file.
Type and Number
Description
Severity
Feature Server Both Links Down
CRITICAL
Index Table Usage Exceeded Critical Usage Threshold Level (IDX Table Usage
Exceeded Critical Usage Threshold Level)
CRITICAL
The Central Processing Unit Usage is Over 90% Busy (The CPU Usage is Over 90%
Busy)
CRITICAL
The Five Minute Load Average is Abnormally High
MAJOR
Memory and Swap are Consumed at Critical Levels
CRITICAL
No Heartbeat Messages Received Through the Interface (No HB Messages Received
Through the Interface)
CRITICAL
Link Monitor: Interface Lost Communication
MAJOR
Outgoing Heartbeat Period Exceeded Limit (Outgoing HB Period Exceeded Limit)
MAJOR
Average Outgoing Heartbeat Period Exceeds Major Alarm Limit (Average Outgoing
HB Period Exceeds Maj Alarm Limit)
MAJOR
Disk Partition Critically Consumed
CRITICAL
Disk Partition Significantly Consumed
MAJOR
The Free Inter-Process Communication Pool Buffers Below Major Threshold (The
Free IPC Pool Buffers Below Major Threshold)
MAJOR
The Free Inter-Process Communication Pool Buffers Below Critical Threshold (The
Free IPC Pool Buffers Below Critical Threshold)
CRITICAL
The Free Inter-Process Communication Pool Buffer Count Below Minimum Required
(The Free IPC Pool Buffer Count Below Minimum Required)
CRITICAL
Average Outgoing Heartbeat Period Exceeds Critical Limit (Average Outgoing HB
Period Exceeds Critical Limit)
CRITICAL
Swap Space Below Major Threshold
MAJOR
Swap Space Below Critical Threshold
CRITICAL
No Heartbeat Messages Received Through Interface From Router (No HB Messages
Received Through Interface From Router)
CRITICAL
Stream Control Transmission Protocol Association Failure (SCTP Association
Failure)
MAJOR
Signaling Gateway Failure
MAJOR
Signaling Gateway Process is Out-of-Service
MAJOR
Message Transfer Part 3 User Adapter Cannot Go Standby (M3UA/SUA Cannot Go
Standby)
MAJOR