![Cisco BTS 10200 Softswitch Troubleshooting Manual Download Page 379](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550379.webp)
10-11
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (18)
To troubleshoot and correct the cause of the alarm, refer to the
Outage—Signaling (18)” section on page 10-134
SIGNALING (19)
To troubleshoot and correct the cause of the alarm, refer to the
“Link Set Inaccessible—Signaling (19)”
.
DESCRIPTION
Link: Remote Processor Outage
SEVERITY
MINOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Link No–ONE_BYTE
Link Name–STRING [8]
PRIMARY
CAUSE
Issued when the specified SS7 link has experienced a processor outage.
PRIMARY
ACTION
Monitor the network level event reports for any events associated with the processing complex used
by the specified SS7 link. Verify that the SS7 link is returned to service.
DESCRIPTION
Link Set Inaccessible
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Link Set No–ONE_BYTE
Link Set Name–STRING [8]
PRIMARY
CAUSE
Issued when the specified SS7 link set is inaccessible.
PRIMARY
ACTION
If the SS7 signaling adapter is not running normally and the associated call agent platform is not active,
return them to service.