Tabular Display of Events and Alarms
Isolating Calls Which Show Internal Symptoms of Problems
To use ERROR and WARN messages isolate calls which show internal symptoms of problems, take the
following steps:
Step 1
Go to the desired target platform log directory.
$ cd /opt/OptiCall/<platform-instance-name>/bin/logs
Step 2
Use the UNIX
grep
command to scan for lines with ERROR or WARN messages.
$ grep "ERROR" *.log
Step 3
If you find a non-zero CTRAC-ID present in the appropriate column in the trace log, it means that the
ERROR occurred while a call was being processed. Note the CTRAC-ID.
Step 4
Use the CTRAC-ID to filter out the trace log lines from the BTS 10200 logs.
Billing Fields
The billing record contains a new parameter that contains the CTRAC-ID related to the feature described
in this document. The CTRAC billing CDR parameter is named CTRACID.
Troubleshooting
The BTS 10200 CTRAC feature is intended as a troubleshooting enabler. No specific troubleshooting
steps are required other than the use of
grep
to filter out the TRACE lines corresponding to a CTRAC-ID.
Tabular Display of Events and Alarms
The BTS 10200 Tabular Display of Events and Alarms feature enables the BTS 10200 to display current
alarms, alarm history and event history in tabular form. The underlying CPI layer modification will
easily facilitate other commands to display their data in tabular form.
The BTS 10200 Tabular Display of Events and Alarms feature enables the BTS 10200 to display current
alarms, alarm history and event history in tabular form. The output of the
show alarm
and the
show
alarm-log
commands will provide a tabular output consisting of one alarm per row. Each of the reported
fields will be columns in the tabular output. This will make the outputs much more conducive to capture
and printing.
CPI layer changes will facilitate the tabular display of alarms. The CPI layer changes will allow the
tabular display of other data through derived Request Managers.