![Cisco BTS 10200 Softswitch Troubleshooting Manual Download Page 265](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550265.webp)
7-33
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 7 Maintenance Troubleshooting
Maintenance Events and Alarms
MAINTENANCE (58)
For additional information, refer to the
“Memory and Swap are Consumed at Abnormal
Levels—Maintenance (58)” section on page 7-79
Note
Maintenance (58) is issued by the BTS 10200 system when memory consumption is greater than 80
percent (>80%) and swap space consumption is greater than 30 percent (>30%).
Note
Refer to the
“Obtaining Documentation and Submitting a Service Request” section on page lvi
detailed instructions on contacting Cisco TAC and opening a service request.
MAINTENANCE (59)
MAINTENANCE (59) is not used.
MAINTENANCE (60)
MAINTENANCE (60) is not used.
DESCRIPTION
Memory and Swap are Consumed at Abnormal Levels
SEVERITY
INFO
THRESHOLD
100
THROTTLE
0
DATAWORDS
Host Name–STRING [40]
Memory–STRING [40]
Swap–STRING [40]
PRIMARY
CAUSE
A process or multiple processes have consumed an abnormal amount of memory on the system and the
operating system is utilizing an abnormal amount of the swap space for process execution. This can be
a result of high call rates or bulk provisioning activity.
PRIMARY
ACTION
Monitor the system to ensure all subsystems are performing normally. If they are, only lightening the
effective load on the system will clear the situation. If they are not, verify which process(es) are
running at abnormally high rates, provide the information to Cisco TAC. (Contact Cisco TAC.)