![Cisco BTS 10200 Softswitch Troubleshooting Manual Download Page 322](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550322.webp)
7-90
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 7 Maintenance Troubleshooting
Troubleshooting Maintenance Alarms
Troubleshooting Maintenance Alarms
This section provides the information needed to troubleshoot and correct maintenance alarms.
lists all of the maintenance alarms in numerical order and provides cross reference to each subsection in
this section.
Table 7-3
BTS 10200 Maintenance Alarms
Alarm Type
Alarm Name
Alarm Severity
MAINTENANCE(3)
Local Side has Become Faulty—Maintenance (3)
MAJOR
MAINTENANCE(4)
Mate Side has Become Faulty—Maintenance (4)
MAJOR
MAINTENANCE(5)
Changeover Failure—Maintenance (5)
MAJOR
MAINTENANCE(6)
Changeover Timeout—Maintenance (6)
MAJOR
MAINTENANCE(7)
Mate Rejected Changeover—Maintenance (7)
MAJOR
MAINTENANCE(8)
Mate Changeover Timeout—Maintenance (8)
MAJOR
MAINTENANCE(9)
Local Initialization Failure—Maintenance (9)
MAJOR
MAINTENANCE(10)
Local Initialization Timeout—Maintenance (10)
MAJOR
MAINTENANCE(18)
Process Manager: Process has Died—Maintenance (18)
MINOR
MAINTENANCE(19)
Process Manager: Process Exceeded Restart Rate—Maintenance (19)
MAJOR
MAINTENANCE(20)
Lost Connection to Mate—Maintenance (20)
MAJOR
MAINTENANCE(21)
Network Interface Down—Maintenance (21)
MAJOR
MAINTENANCE(23)
Process Manager: Process Failed to Complete Initialization—Maintenance (23)
MAJOR
MAINTENANCE(24)
Process Manager: Restarting Process—Maintenance (24)
MINOR
MAINTENANCE(26)
Process Manager: Going Faulty—Maintenance (26)
MAJOR
MAINTENANCE(40)
Process Manager: Binary Does not Exist for Process—Maintenance (40)
CRITICAL
MAINTENANCE(42)
Number of Heartbeat Messages Received is Less Than 50% of
Expected—Maintenance (42)
MAJOR
MAINTENANCE(43)
Process Manager: Process Failed to Come Up in Active Mode—Maintenance (43)
CRITICAL
MAINTENANCE(44)
Process Manager: Process Failed to Come Up in Standby Mode—Maintenance
(44)
CRITICAL
MAINTENANCE(45)
Application Instance State Change Failure—Maintenance (45)
MAJOR
MAINTENANCE(47)
Thread Watchdog Counter Expired for a Thread—Maintenance (47)
CRITICAL
MAINTENANCE(48)
Index Table Usage Exceeded Minor Usage Threshold Level—Maintenance (48)
MINOR
MAINTENANCE(49)
Index Table Usage Exceeded Major Usage Threshold Level—Maintenance (49)
MAJOR
MAINTENANCE(50)
Index Table Usage Exceeded Critical Usage Threshold Level—Maintenance (50)
CRITICAL
MAINTENANCE(51)
A Process Exceeds 70% of Central Processing Unit Usage—Maintenance (51)
MAJOR
MAINTENANCE(53)
The Central Processing Unit Usage is Over 90% Busy—Maintenance (53)
CRITICAL
MAINTENANCE(55)
The Five Minute Load Average is Abnormally High—Maintenance (55)
MAJOR
MAINTENANCE(57)
Memory and Swap are Consumed at Critical Levels—Maintenance (57)
CRITICAL
MAINTENANCE(61)
No Heartbeat Messages Received Through the Interface—Maintenance (61)
CRITICAL
MAINTENANCE(62)
Link Monitor: Interface Lost Communication—Maintenance (62)
MAJOR