Chapter 7 Maintenance Troubleshooting
Monitoring Maintenance Events
Resource Reset Failure—Maintenance (81)
The Resource Reset Failure event functions as an informational alert that a resource reset has failed. The
primary cause of the event an internal messaging error. Check dataword three (failure reason) to
determine if this is caused by invalid user input, inconsistent provisioning of the device, or if the system
is busy and a timeout occurred.
Average Outgoing Heartbeat Period Exceeds Critical Limit—Maintenance (82)
The Average Outgoing Heartbeat Period Exceeds Critical Limit alarm (critical) indicates that the
average outgoing HB period has exceeded the critical limit threshold. To troubleshoot and correct the
cause of the Average Outgoing Heartbeat Period Exceeds Critical Limit alarm, refer to the
Outgoing Heartbeat Period Exceeds Critical Limit—Maintenance (82)” section on page 7-106
.
Swap Space Below Minor Threshold—Maintenance (83)
The Swap Space Below Minor Threshold alarm (minor) indicates that the swap space has fallen below
the minor threshold level. To troubleshoot and correct the cause of the Swap Space Below Minor
Threshold alarm, refer to the
“Swap Space Below Minor Threshold—Maintenance (83)” section on
.
Swap Space Below Major Threshold—Maintenance (84)
The Swap Space Below Major Threshold alarm (major) indicates that the swap space has fallen below
the major threshold level. To troubleshoot and correct the cause of the Swap Space Below Major
Threshold alarm, refer to the
“Swap Space Below Major Threshold—Maintenance (84)” section on
.
Swap Space Below Critical Threshold—Maintenance (85)
The Swap Space Below Critical Threshold alarm (critical) indicates that the swap space has fallen below
the critical threshold level. To troubleshoot and correct the cause of the Swap Space Below Major
Threshold alarm, refer to the
“Swap Space Below Critical Threshold—Maintenance (85)” section on
.
System Health Report Collection Error—Maintenance (86)
The System Health Report Collection Error alarm (minor) indicates that an error occurred while
collecting System Health Report. To troubleshoot and correct the cause of the System Health Report
Collection Error alarm, refer to the
“System Health Report Collection Error—Maintenance (86)” section