15-44
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 15 Diagnostic Tests
Network Loopback Test for Network-based Call Signaling/Media Gateway Control Protocol Endpoints
Dedicated NLB Testing Device Configuration Example
Note
The following is an example of provisioning a dedicated testing trunk-grp for testing network loop-back
on a subscriber line. Change TEST-LINE-TYPE to different values (other than NTE) to change test
origination type.
Use the following procedure as a dedicated NLB testing device configuration example.
Step 1
Add MGW profile.
add mgw-profile id=BRIX; vendor=Tollgrade; mgcp-version=mgcp_1_0; MGCP-VARIANT=NCS-1-0;
Step 2
Add cas-tg-profile.
add cas-tg-profile id=BRIX_TG; sig-type=LINE; TEST-LINE=Y; TEST-LINE-TYPE=NLB-LINE-TEST
Step 3
Add MGW.
add mgw id=brix1; tsap-addr=<mgw DNS / IP address>; mgw-profile-id=BRIX; type=TGW;
call-agent id=CA146;
Step 4
Add trunk-grp.
add trunk-grp id=100; call-agent-id=CA146; tg-type=CAS; cas-tg-profile=BRIX_TG;
mgcp-pkg-type=LINE
Step 5
Add termination.
add termination prefix=aaln/; port-start=1; port-end=2; type=TRUNK; mgw-id=c925.172;
Step 6
Add trunk.
add trunk termination-prefix=aaln/; termination-port-start=1; termination-port-end=2;
cic-start=1; cic-end=2; tgn-id=100