7-48
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 7 Maintenance Troubleshooting
Maintenance Events and Alarms
MAINTENANCE (90)
To troubleshoot and correct the cause of the alarm, refer to the
Consumed—Maintenance (90)” section on page 7-107
.
MAINTENANCE (91)
To troubleshoot and correct the cause of the alarm, refer to the
“Internet Protocol Manager Configuration
File Error—Maintenance (91)” section on page 7-107
DESCRIPTION
Disk Partition Moderately Consumed
SEVERITY
MINOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Directory–STRING [32]
Device–STRING [32]
Percentage Used–STRING [8]
PRIMARY
CAUSE
A process or processes is/are writing extraneous data to the named partition.
PRIMARY
ACTION
Perform disk clean-up and maintenance on the offending system.
DESCRIPTION
Internet Protocol Manager Configuration File Error (IPM Config File Error)
SEVERITY
CRITICAL
THRESHOLD
100
THROTTLE
0
DATAWORDS
Reason–STRING [128]
PRIMARY
CAUSE
The Internet Protocol Manager (IPM) has a configuration file error.
PRIMARY
ACTION
Check the IPM configuration file (ipm.cfg) for incorrect syntax.