![Cisco BTS 10200 Softswitch Troubleshooting Manual Download Page 699](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550699.webp)
15-73
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 15 Diagnostic Tests
Enhanced Traffic Measurement
Measurement Report Summaries
The Cisco BTS 10200 system provides a command line interface (CLI) command to query summary
reports of measurement data from the database on the Element Management System (EMS). This
mechanism provides the ability to specify an interval and the particular type and source of data. The time
interval specified must be prior to the current collection interval.
The following are examples of the command line queries to generate reports on the various types of
measurements collected from the designated call agents and feature servers from 10 am until noon on
March 27th, 2002 and places the data into CSV files for FTP.
Note
Any measurement counters that do not contain data for a given interval are suppressed out of the reports
generated. Only counters that were pegged are presented in the resulting summaries.
report measurement-isdn-summary start-time=2002-03-27 10:00:00; end-time=2002-03-27
12:00:00; call-agent-id=CA146; output=isdn-report; output-type=csv;
report measurement-callp-summary start-time=2002-03-27 10:00:00; end-time=2002-03-27
12:00:00; call-agent-id= CA146; output=callp-report; output-type=csv;
report measurement-mgcp-summary start-time=2002-03-27 10:00:00; end-time=2002-03-27
12:00:00; call-agent-id= CA146; output=mgcp-report; output-type=csv;
report measurement-sim-summary start-time=2002-03-27 10:00:00; end-time=2002-03-27
12:00:00; call-agent-id= CA146; output=sim-report; output-type=csv;
report measurement-pots-local-summary start-time=2002-03-27 10:00:00; end-time=2002-03-27
12:00:00; feature-server-id=PCT01; output=pots-local-report; output-type=csv;
report measurement-pots-misc-summary start-time=2002-03-27 10:00:00; end-time=2002-03-27
12:00:00; feature-server-id=PCT01; output=pots-misc-report; output-type=csv;
report measurement-pots-sle-summary start-time=2002-03-27 10:00:00; end-time=2002-03-27
12:00:00; feature-server-id=PCT01; output=pots-sle-report; output-type=csv;
report measurement-pots-acar-summary start-time=2002-03-27 10:00:00; end-time=2002-03-27
12:00:00; feature-server-id=PCT01; output=pots-acar-report; output-type=csv;
report measurement-pots-cos-summary start-time=2002-03-27 10:00:00; end-time=2002-03-27
12:00:00; feature-server-id=PCT01; output=pots-cos-report; output-type=csv;
report measurement-pots-cot-summary start-time=2002-03-27 10:00:00; end-time=2002-03-27
12:00:00; feature-server-id=PCT01; output=pots-cot-report; output-type=csv;
report measurement-ainsvc-summary start-time=2002-03-27 10:00:00; end-time=2002-03-27
12:00:00; feature-server-id=AIN01; output=ainsvc-report; output-type=csv;
report measurement-sccp-summary start-time=2002-03-27 10:00:00; end-time=2002-03-27
12:00:00; feature-server-id=AIN01; output=sccp-report; output-type=csv;
report measurement-tcap-summary start-time=2002-03-27 10:00:00; end-time=2002-03-27
12:00:00; feature-server-id=AIN01; output=tcap-report; output-type=csv;
report measurement-m3ua-summary start-time=2002-03-27 10:00:00; end-time=2002-03-27
12:00:00; sgp-id=sg-001; output=m3ua-report; output-type=csv;
report measurement-sua-summary start-time=2002-03-27 10:00:00; end-time=2002-03-27
12:00:00; sgp-id=sg-001; output=sua-report; output-type=csv;