Maintenance Events and Alarms
MAINTENANCE (6)
To troubleshoot and correct the cause of the alarm, refer to the
“Changeover Timeout—Maintenance (6)”
Note
Refer to the
“Obtaining Documentation and Submitting a Service Request” section on page lvi
detailed instructions on contacting Cisco TAC and opening a service request.
DESCRIPTION
Keep Alive Module: Changeover Timeout (KAM: Changeover Timeout)
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Local State–STRING [30]
Mate State–STRING [30]
PRIMARY
CAUSE
The system failed to changeover within the required time period. Soon after this event is issued, one
platform will go to the faulty state.
PRIMARY
ACTION
Review the information from CLI log report.
SECONDARY
CAUSE
This alarm is usually caused by a software problem on the specific platform identified in the alarm
report.
SECONDARY
ACTION
Restart the platform identified in the alarm report.
TERNARY
ACTION
If platform restart is not successful, reinstall the application for this platform, and then restart the
platform again.
SUBSEQUENT
ACTION
If necessary, reboot the host machine this platform is located on. Then reinstall and restart all
applications on this machine. If faulty state is a commonly occurring event, then the operating system
(OS) or a hardware failure may be the problem. Contact Cisco TAC for assistance. It may also be