![Cisco BTS 10200 Softswitch Troubleshooting Manual Download Page 636](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550636.webp)
15-10
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 15 Diagnostic Tests
Integrated Services Digital Network Trunk Termination Tests
Integrated Services Digital Network Trunk Termination Tests
This section describes the tests that can be performed on Integrated Services Digital Network (ISDN)
trunk terminations. All terminations must be in the MAINT state for testing.
Step 1
Force the ISDN trunk termination into MAINT state:
control isdn-trunk-termination tgn-id=17; mode=forced; target-state=maint;
Step 2
Display the Test Menu.
diag isdn-trunk-termination
Reply Example:
Reply: Diagnostic ISDN Trunk Group Menu.
===
(1) ISDN MGCP Connectivity Test
(2) ISDN Termination Connection Test
(3) ALL
Note
Test #1 tests if MGCP has access to the ISDN termination.
Test #2 tests if there is a path to the device (ping).
Test #3 performs tests 1 and 2.
Step 3
To perform a specific test, use the following examples as a guide.
diag isdn-trunk-termination test=1; tgn-id=17; cic=1;
Reply Example:
TRUNK DIAGNOSTIC TEST EXECUTED -> diag trunk
TG-NUM -> 17
CIC -> 1
TEST-TYPE -> ADM-MGW-MGCP-CONNECTIVITY-TEST
TEST-DURATION -> 0
RESULT -> TEST-SUCCESS
REASON -> PASSED: Reason: AUEP-NACK received with RespCode = 510
Reply: Diagnostic command executed.
diag isdn-trunk-termination test=2; tgn-id=17; cic=1;
Reply Example:
TRUNK DIAGNOSTIC TEST EXECUTED -> diag trunk
TG-NUM -> 17
CIC -> 1
TEST-TYPE -> ADM-TERM-CONNECTION-TEST
TEST-DURATION -> 0
RESULT -> TEST-SUCCESS
REASON -> PASSED: Reason: AUEP-NACK received with RespCode = 510
Reply: Diagnostic command executed.
Step 4
Force the ISDN trunk termination into MAINT state:
control isdn-trunk-termination tgn-id=17; mode=forced; target-state=maint;