Step 3
To perform a specific test, use the following examples as a guide.
diag mgw id=ubr-03; test=1;
Reply Example:
MEDIA GATEWAY LINE DIAGNOSTIC TEST EXECUTED -> diag mgw
ID -> ubr-03
TEST-TYPE -> ADM-MGW-NETW-CONNECTIVITY-TEST
TEST-DURATION -> 0
RESULT -> TEST-SUCCESS
REASON -> PASSED
Reply: Diagnostic command executed.
diag mgw id=ubr-03; test=2;
Reply Example:
MEDIA GATEWAY LINE DIAGNOSTIC TEST EXECUTED -> diag mgw
ID -> ubr-03
TEST-TYPE -> ADM-MGW-MGCP-CONNECTIVITY-TEST
TEST-DURATION -> 0
RESULT -> TEST-SUCCESS
REASON -> PASSED
Reply: Diagnostic command executed.
diag mgw id=ubr-03; test=3;
Reply Example:
MEDIA GATEWAY LINE DIAGNOSTIC TEST EXECUTED -> diag mgw
ID -> ubr-03
TEST-TYPE -> ADM-MGW-NETW-CONNECTIVITY-TEST
TEST-DURATION -> 11
RESULT -> TEST-SUCCESS
REASON -> PASSED
MEDIA GATEWAY LINE DIAGNOSTIC TEST EXECUTED -> diag mgw
ID -> ubr-03
TEST-TYPE -> ADM-MGW-MGCP-CONNECTIVITY-TEST
TEST-DURATION -> 0
RESULT -> TEST-SUCCESS
REASON -> PASSED
Reply: Diagnostic command executed.
Step 4
Force the media gateway into INS state:
control mgw id=c2421.65; mode=forced; target-state=ins;
Reply Example:
Reply : Success: CLI change successful
MGW ID -> c2421.65
INITIAL STATE -> ADMIN_MAINT
REQUEST STATE -> ADMIN_INS
RESULT STATE -> ADMIN_INS
FAIL REASON -> ADM found no failure
REASON -> ADM executed successful
RESULT -> ADM configure result in success