Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 17 Disk Replacement
Call Agent/Feature Server or Element Management System Disk 1 Replacement
Call Agent/Feature Server or Element Management System Disk
1 Replacement
Note
The letter "x" in cxt0d0 or cxt1d0 throughout the procedure is referring to the SCSI controller ID of the
system (either 0 or 1). To find out the controller ID, use the
format
command.
Step 1
Login as root.
Step 2
Verify application status.
<hostname>#
nodestat
Note
If all platforms on this node are ACTIVE, then you need to switchover to STANDBY side using the CLI
command.
Step 3
Stop all BTS 10200 platforms.
<hostname>#
platform stop all
Step 4
Perform the following commands to detach all submirror metadevice.
<hostname>#
metadetach –f d2 d1
<hostname>#
metadetach –f d14 d13
<hostname>#
metadetach –f d11 d10
<hostname>#
metadetach –f d5 d4
<hostname>#
metadetach –f d8 d7
Step 5
Perform the following commands to clear all submirror metadevice.
<hostname>#
metaclear d1
<hostname>#
metaclear d13
<hostname>#
metaclear d10
<hostname>#
metaclear d4
<hostname>#
metaclear d7
Step 6
Delete database replica on defective disk.
<hostname>#
metadb –d –f /dev/dsk/cxt1d0s4
Step 7
Verify that there is no existing metadevice on defective disk.
<hostname>#
metastat –p |grep cxt1d0