![Cisco BTS 10200 Softswitch Troubleshooting Manual Download Page 125](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550125.webp)
3-19
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 3 Billing Troubleshooting
Billing Events and Alarms
BILLING (44)
To troubleshoot and correct the cause of the alarm, refer to the
Occurred—Billing (44)” section on page 3-40
BILLING (45)
To troubleshoot and correct the cause of the alarm, refer to the
Opened—Billing (45)” section on page 3-41
.
DESCRIPTION
Record Keeping System Switch Occurred (RKS Switch Occurred)
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Type of RKS Switch–STRING [20]
Location Tag–STRING [30]
PRIMARY
CAUSE
Billing changed the destination RKS to which event messages are transmitted. The change could have
been triggered by a communication problem with an RKS, or by an attempt to reestablish RKS
communication.
PRIMARY
ACTION
No action is necessary.
DESCRIPTION
Event Message Log File Opened
SEVERITY
MINOR
THRESHOLD
50
THROTTLE
0
DATAWORDS
Element Type–STRING [5]
File Name–STRING [60]
Location Tag–STRING [30]
PRIMARY
CAUSE
A log file has been created for the storage of event messages that cannot be transmitted to an RKS.
PRIMARY
ACTION
No action is necessary.