10-25
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (40)
To troubleshoot and correct the cause of the alarm, refer to the
“Trunk Remotely Blocked—Signaling
.
SIGNALING (41)
SIGNALING (41) is not used.
SIGNALING (42)
For additional information, refer to the
“Continuity Testing Message Received on the Specified Circuit
Identification Code—Signaling (42)” section on page 10-103
.
DESCRIPTION
Trunk Remotely Blocked
SEVERITY
MAJOR
THRESHOLD
500
THROTTLE
0
DATAWORDS
CIC Number–STRING [40]
TGN-ID–FOUR_BYTES
DPC–STRING [20]
OPC–STRING [20]
MGW-EP-NAME–STRING [64]
MGW-TSAP-ADDR–STRING [80]
PRIMARY
CAUSE
Issued when a BLO or CGB message was received on the specified CIC if it is SS7 trunk. Issued when
a SERVICE OOS message is received for Integrated Services Digital Network (ISDN) trunks. Issued
when Reverse Make Busy (RBZ) signal is received for channel-associated signaling (CAS) operator
trunk.
PRIMARY
ACTION
No action required. Can manually recover from this condition locally by controlling the effected trunks
to the unequipped (UEQP) state and back to the INS state.
DESCRIPTION
Continuity Testing Message Received on the Specified Circuit Identification Code (COT Message
Received on the Specified CIC)
SEVERITY
INFO
THRESHOLD
100
THROTTLE
0
DATAWORDS
CIC Number–TWO_BYTES
TGN-ID–FOUR_BYTES
DPC–STRING [20]
OPC–STRING [20]
PRIMARY
CAUSE
Issued when a continuity testing (COT) message was received on the specified CIC.
PRIMARY
ACTION
No action required.