![Cisco BTS 10200 Softswitch Troubleshooting Manual Download Page 253](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550253.webp)
7-21
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 7 Maintenance Troubleshooting
Maintenance Events and Alarms
MAINTENANCE (34)
For additional information, refer to the
“Process Manager: Sending End Process to
Process—Maintenance (34)” section on page 7-74
MAINTENANCE (35)
For additional information, refer to the
“Process Manager: All Processes Completed
Initialization—Maintenance (35)” section on page 7-75
DESCRIPTION
Process Manager: Sending End Process to Process (PMG: Sending End Process to Process)
SEVERITY
INFO
THRESHOLD
100
THROTTLE
0
DATAWORDS
Process Name–STRING [40]
Process Group–ONE_BYTE
PRIMARY
CAUSE
The process is being notified to exit gracefully as the system is switching over to the standby state, or
it is shutting down. The switchover or shutdown could be due to either of the following: (1) The
operator is taking the action to switch or shut down the system. (2) The system has detected a fault.
PRIMARY
ACTION
No action is necessary.
DESCRIPTION
Process Manager: All Processes Completed Initialization (PMG: All Processes Completed
Initialization)
SEVERITY
INFO
THRESHOLD
100
THROTTLE
0
PRIMARY
CAUSE
The system is being brought up, and all processes are ready to start executing.
PRIMARY
ACTION
No action is necessary.