Monitoring Signaling Events
Session Initiation Protocol Element Provisioned with Service Enabled is
Internally Disabled—Signaling (169)
The Session Initiation Protocol Element Provisioned with Service Enabled is Internally Disabled event
functions as an informational alert that a SIP element was provisioned with SRV enabled and is
associated to at least one or more Server Groups. The SRV flag will be assumed disabled. However, to
resolve this informational message, provision the SRV flag disabled on the SIP element.
Residential Gateway Endpoints are out of Service at the Gateway—Signaling
(170)
The Residential Gateway Endpoints are out of Service at the Gateway alarm (minor) indicates that the
residential gateway has been administratively taken OOS using the command at the gateway. To
troubleshoot and correct the primary cause of the Residential Gateway Endpoints are out of Service at
the Gateway alarm, refer to the
“Residential Gateway Endpoints are out of Service at the
Gateway—Signaling (170)” section on page 10-158
.
Residential Gateway Unreachable—Signaling (171)
The Residential Gateway Unreachable alarm (minor) indicates that a MGCP signaling interop error has
occurred with the residential media gateway. To troubleshoot and correct the primary cause of the
Residential Gateway Unreachable alarm, refer to the
“Residential Gateway Unreachable—Signaling
.
Multimedia Terminal Adapter Effective-Aggr-Id Becomes Unavailable Due to
Its IP Address—Signaling (172)
The Multimedia Terminal Adapter Effective-Aggr-Id Becomes Unavailable Due to Its IP Address alarm
(major) indicates that the MTA has been moved to new subnet which is not provisioned, or provisioned
with the aggr-id=NULL. To troubleshoot and correct the primary cause of the Multimedia Terminal
Adapter Effective-Aggr-Id Becomes Unavailable Due to Its IP Address alarm, refer to the
.
ENUM Server Domain Cannot be Resolved Into Any IP Address —Signaling
(173)
The ENUM Server Domain Cannot be Resolved Into Any IP Address alarm (critical) indicates that a
misconfiguration has occurred in the DNS configuration. To troubleshoot and correct the cause of the
ENUM Server Domain Cannot be Resolved Into Any IP Address alarm, refer to the
Domain Cannot be Resolved Into Any IP Address —Signaling (173)” section on page 10-159