10-18
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (29)
To monitor and correct the cause of the event, refer to the
Message—Signaling (29)” section on page 10-102
DESCRIPTION
Unanswered Circuit Query Message (Unanswered CQM)
SEVERITY
WARNING
THRESHOLD
100
THROTTLE
0
DATAWORDS
CIC Number–TWO_BYTES
TGN-ID–FOUR_BYTES
DPC–STRING [20]
OPC–STRING [20]
PRIMARY
CAUSE
Issued when a circuit query message (CQM) message was not acknowledged before the timer 28 (T28)
expired for the associated CIC.
PRIMARY
ACTION
Verify that the SS7 signaling adapter processes is running normally.
SECONDARY
ACTION
Verify that the call agent platform is active. Verify that the SS7 interface hardware is in service.
TERNARY
ACTION
Verify that the associated SS7 signaling link is available.
SUBSEQUENT
ACTION
Verify that the T13 timer is set to an appropriate level. Verify that the SS7 link is not congested.