10-89
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (171)
To troubleshoot and correct the cause of the alarm, refer to the
Unreachable—Signaling (171)” section on page 10-158
SIGNALING (172)
To troubleshoot and correct the cause of the alarm, refer to the
Effective-Aggr-Id Becomes Unavailable Due to Its IP Address—Signaling (172)” section on
page 10-158
DESCRIPTION
Residential Gateway Unreachable
SEVERITY
MINOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Entity Name–STRING [40]
General Context–STRING [40]
Specific Context–STRING [40]
Failure Context–STRING [40]
PRIMARY
CAUSE
A MGCP signaling interop error has occurred with the residential media gateway.
PRIMARY
ACTION
Check the IP connectivity status between BTS 10200 call agent and the trunking gateway. If the
residential gateway is not physically connected, but controlled INS at the BTS 10200.
DESCRIPTION
Multimedia Terminal Adapter Effective-Aggr-Id Becomes Unavailable Due to its IP Address (MTA
Effective-Aggr-Id Becomes Unavailable Due to its IP Address)
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
MTA IP Address–STRING [64]
PRIMARY
CAUSE
The MTA has been moved to new subnet which is not provisioned, or provisioned with the
aggr-id=NULL.
PRIMARY
ACTION
Provision the subnet aggr-id for the MTA.