12-4
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 12 System Troubleshooting
System Events and Alarms
SYSTEM (4)
To troubleshoot and correct the cause of the alarm, refer to the
“Inter-Process Communication Message
Send Failure—System (4)” section on page 12-15
Note
Refer to the
“Obtaining Documentation and Submitting a Service Request” section on page lvi
for
detailed instructions on contacting Cisco TAC and opening a service request.
DESCRIPTION
Inter-Process Communication Message Send Failure (IPC Message Send Failure)
SEVERITY
MINOR
THRESHOLD
50
THROTTLE
0
DATAWORDS
Error Code–FOUR_BYTES
Destination Process–FOUR_BYTES
Message Number–FOUR_BYTES
Location Tag–STRING [30]
PRIMARY
CAUSE
The process for which the message is intended is not running.
PRIMARY
ACTION
Check to ensure that all components or processes are running. Attempt to restart any component or
process that is not running.
SECONDARY
CAUSE
An internal error has occurred.
SECONDARY
ACTION
If the problem persists, call Cisco TAC. (Contact Cisco TAC.)