7-18
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 7 Maintenance Troubleshooting
Maintenance Events and Alarms
MAINTENANCE (26)
To troubleshoot and correct the cause of the alarm, refer to the
Faulty—Maintenance (26)” section on page 7-99
.
MAINTENANCE (27)
For additional information, refer to the
“Process Manager: Changing Over to Active—Maintenance
.
MAINTENANCE (28)
For additional information, refer to the
“Process Manager: Changing Over to Standby—Maintenance
.
DESCRIPTION
Process Manager: Going Faulty (PMG: Going Faulty)
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Reason–STRING [40]
PRIMARY
CAUSE
The system has been brought down because the system has detected a fault.
PRIMARY
ACTION
If it is not due to the operator intentionally bringing down the system, then the platform has detected
a fault and has shut down. This is typically followed by a MAINTENANCE (3) alarm event. Use
corrective action procedures provided for the MAINTENANCE (3) alarm event.
DESCRIPTION
Process Manager: Changing Over to Active (PMG: Changing Over to Active)
SEVERITY
INFO
THRESHOLD
100
THROTTLE
0
DESCRIPTION
Process Manager: Changing Over to Standby (PMG: Changing Over to Standby)
SEVERITY
INFO
THRESHOLD
100
THROTTLE
0