![Cisco BTS 10200 Softswitch Troubleshooting Manual Download Page 401](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550401.webp)
10-33
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (60)
To monitor and correct the cause of the event, refer to the
“Integrated Services Digital Network STATUS
Message Containing Error Indication Received—Signaling (60)” section on page 10-106
SIGNALING (61)
For additional information, refer to the
“Trunk Operational State Changed by Service
Message—Signaling (61)” section on page 10-106
.
DESCRIPTION
Integrated Services Digital Network STATUS Message Containing Error Indication Received (ISDN
STATUS Message Containing Error Indication Received)
SEVERITY
WARNING
THRESHOLD
100
THROTTLE
0
DATAWORDS
Termination Name–STRING [40]
Termination Index–FOUR_BYTES
Trunk Group ID–FOUR_BYTES
Trunk Group Index–FOUR_BYTES
Cause Value–ONE_BYTE
Call State–ONE_BYTE
PRIMARY
CAUSE
Issued when an ISDN status message was received containing an error indication for the specified
termination.
PRIMARY
ACTION
If the specified termination is not operating normally, place it in the service state.
DESCRIPTION
Trunk Operational State Changed by Service Message
SEVERITY
INFO
THRESHOLD
100
THROTTLE
0
DATAWORDS
Termination Name–STRING [40]
Termination Index–FOUR_BYTES
Trunk Group ID–FOUR_BYTES
Trunk Group Index–FOUR_BYTES
Service Status–FOUR_BYTES
PRIMARY
CAUSE
Issued when the specified trunk group’s operational status was changed by a service message from the
specified gateway.
PRIMARY
ACTION
Monitor the event reports at the network level to verify that the specified gateway and terminations are
operating normally.