![Cisco BTS 10200 Softswitch Troubleshooting Manual Download Page 203](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550203.webp)
6-9
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 6 Database Troubleshooting
Database Events and Alarms
DATABASE (10)
To troubleshoot and correct the cause of the alarm, refer to the
“Element Management System Database:
Backup Fails—Database (10)” section on page 6-31
.
DESCRIPTION
Element Management System Database: Backup Fails (EMS Database: Backup Fails)
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Host Name–STRING [30]
Database Name–STRING [10]
Message 1–STRING [200]
Message 2–STRING [200]
Time Stamp–STRING [20]
PRIMARY
CAUSE
The system or hardware are unstable.
PRIMARY
ACTION
Re-start backup process.