![Cisco BTS 10200 Softswitch Troubleshooting Manual Download Page 432](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550432.webp)
10-64
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (116)
To troubleshoot and correct the cause of the alarm, refer to the
“Destination Point Code User Part
Unavailable—Signaling (116)” section on page 10-153
SIGNALING (117)
To troubleshoot and correct the cause of the alarm, refer to the
“Circuit Validation Test Message
Received for an Unequipped Circuit Identification Code—Signaling (117)” section on page 10-153
DESCRIPTION
Destination Point Code User Part Unavailable (DPC User Part Unavailable)
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
DPC ID–STRING [17]
PRIMARY
CAUSE
A SGP sent a destination user part unavailable (DUPU) M3UA message to the CA indicating that a
User Part is unavailable on a DPC.
PRIMARY
ACTION
Contact the SS7 Network Administrator to report the User Part Unavailable problem on the DPC so
that communication can be restored.
DESCRIPTION
Circuit Validation Test Message Received for an Unequipped Circuit Identification Code (CVT
Message Received for an Unequipped CIC)
SEVERITY
MINOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
CIC–TWO_BYTES
TGN-ID–EIGHT_BYTES
DPC–STRING [13]
PRIMARY
CAUSE
The CIC is not provisioned
PRIMARY
ACTION
Provision the CIC.