Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 7 Maintenance Troubleshooting
Maintenance Events and Alarms
MAINTENANCE (75)
To monitor and correct the cause of the event, refer to the
“Mismatch of Internet Protocol Address Local
Server and Domain Name System—Maintenance (75)” section on page 7-82
.
MAINTENANCE (76)
MAINTENANCE (76) is not used.
MAINTENANCE (77)
To troubleshoot and correct the cause of the alarm, refer to the
Tolerance—Maintenance (77)” section on page 7-106
DESCRIPTION
Mismatch of Internet Protocol Address Local Server and Domain Name System (Mismatch of IP Addr
% Local Server and DNS)
SEVERITY
WARNING
THRESHOLD
100
THROTTLE
0
DATAWORDS
Host Name–STRING [64]
IP Addr Local Server–STRING [64]
IP Addr DNS Server–STRING [64]
PRIMARY
CAUSE
The DNS updates are not getting to the BTS 10200 from the external server or the discrepancy was
detected before the local DNS lookup table was updated.
PRIMARY
ACTION
Ensure that the external DNS server is operational and is sending updates to the BTS 10200.
DESCRIPTION
Mate Time Differs Beyond Tolerance
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Max Time Difference–FOUR_BYTES
Actual Time Difference–FOUR_BYTES
PRIMARY
CAUSE
Time synchronization is not working.
PRIMARY
ACTION
Change UNIX time on the Faulty/Standby side. If Standby, stop the platform first.