![Cisco BTS 10200 Softswitch Troubleshooting Manual Download Page 411](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550411.webp)
10-43
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (80)
To troubleshoot and correct the cause of the alarm, refer to the
Error—Signaling (80)” section on page 10-139
Note
Refer to the
“Obtaining Documentation and Submitting a Service Request” section on page lvi
detailed instructions on contacting Cisco TAC and opening a service request.
DESCRIPTION
Out of Bounds, Memory/Socket Error
SEVERITY
CRITICAL
DATAWORDS
Process Name–STRING [40]
Description–STRING [40]
Extra Info–STRING [40]
PRIMARY
CAUSE
Out of heap memory.
PRIMARY
ACTION
Notify customer support. Increase the random access memory (RAM). (Contact Cisco TAC.)
SECONDARY
CAUSE
Out of IPC pool memory.
SECONDARY
ACTION
Resize the IPC pool size in the platform configuration file.
TERNARY
CAUSE
A socket error has occurred. An inappropriate or already bound socket is in use.
TERNARY
ACTION
Check the UDP port supplied with the media gateway adapter (MGA) command-line for validity and
prior use.