![Cisco BTS 10200 Softswitch Troubleshooting Manual Download Page 395](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550395.webp)
10-27
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (45)
For additional information, refer to the
“Circuit is UNEQUIPPED on Remote Side—Signaling (45)”
.
SIGNALING (46)
For additional information, refer to the
“Specified Circuit Identification Code is Invalid for the
Operation—Signaling (46)” section on page 10-104
.
SIGNALING (47)
SIGNALING (47) is not used.
SIGNALING (48)
SIGNALING (48) is not used.
DESCRIPTION
Circuit is UNEQUIPPED on Remote Side
SEVERITY
INFO
THRESHOLD
100
THROTTLE
0
DATAWORDS
CIC Number–TWO_BYTES
TGN-ID–FOUR_BYTES
DPC–STRING [20]
OPC–STRING [20]
PRIMARY
CAUSE
Issued when an unequipped circuit has been detected on the remote side.
PRIMARY
ACTION
Monitor the event reports at the network level to verify if an existing circuit was unequipped causing
a status mismatch with the local end.
DESCRIPTION
Specified Circuit Identification Code is Invalid for the Operation (Specified CIC is Invalid for the
Operation)
SEVERITY
INFO
THRESHOLD
100
THROTTLE
0
DATAWORDS
CIC Number–TWO_BYTES
TGN-ID–FOUR_BYTES
DPC–STRING [20]
OPC–STRING [20]
PRIMARY
CAUSE
Issued when an invalid operation was performed on the specified CIC.
PRIMARY
ACTION
Verify that the SS7 provisioning tables are properly configured at the circuit level.