3-18
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 3 Billing Troubleshooting
Billing Events and Alarms
BILLING (42)
To monitor and correct the cause of the event, refer to the
“Error Reading Provisioned Data–Using
Default—Billing (42)” section on page 3-31
.
Note
Refer to the
“Obtaining Documentation and Submitting a Service Request” section on page lvi
for
detailed instructions on contacting Cisco TAC and opening a service request.
BILLING (43)
BILLING (43) is not used.
DESCRIPTION
Error Reading Provisioned Data–Using Default
SEVERITY
WARNING
THRESHOLD
100
THROTTLE
0
DATAWORDS
Error Code–FOUR_BYTES
Table Name–STRING [20]
Field Name–STRING [20]
Default Value (Decim–FOUR_BYTES
Default Value (Text)–STRING [20]
Location Tag–STRING [30]
PRIMARY
CAUSE
An application was unable to read the provisioned data, and had to resort to using default values.
PRIMARY
ACTION
Check to ensure that a complete load has been installed on the system. If the load is complete and
problem persists, call Cisco TAC. (Contact Cisco TAC.)