![Cisco BTS 10200 Softswitch Troubleshooting Manual Download Page 537](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550537.webp)
11-9
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 11 Statistics Troubleshooting
Statistics Events and Alarms
STATISTICS (12)
To troubleshoot and correct the cause of the alarm, refer to the
“Measurement Handshake Error–Schema
Inconsistency—Statistics (12)” section on page 11-17
.
DESCRIPTION
Measurement Handshake Error–Schema Inconsistency
SEVERITY
MAJOR
THRESHOLD
5
THROTTLE
0
DATAWORDS
Schemas Out of Synchronization–STRING [64]
PRIMARY
CAUSE
Counters were added or deleted from the schema in Oracle but not in the call agent.
PRIMARY
ACTION
Add or delete the counters on the CA.
SECONDARY
CAUSE
Load is installed incorrectly.
SECONDARY
ACTION
Reinstall the load.