![Cisco BTS 10200 Softswitch Troubleshooting Manual Download Page 276](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550276.webp)
7-44
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 7 Maintenance Troubleshooting
Maintenance Events and Alarms
MAINTENANCE (82)
To troubleshoot and correct the cause of the alarm, refer to the
“Average Outgoing Heartbeat Period
Exceeds Critical Limit—Maintenance (82)” section on page 7-106
.
MAINTENANCE (83)
To troubleshoot and correct the cause of the alarm, refer to the
Threshold—Maintenance (83)” section on page 7-106
.
DESCRIPTION
Average Outgoing Heartbeat Period Exceeds Critical Limit (Average Outgoing HB Period Exceeds
Critical Limit)
SEVERITY
CRITICAL
THRESHOLD
100
THROTTLE
0
DATAWORDS
Critical Threshold F–FOUR_BYTES
Current Average HB Peri–FOUR_BYTES
PRIMARY
CAUSE
The CPU is overloaded.
PRIMARY
ACTION
Shutdown the platform.
DESCRIPTION
Swap Space Below Minor Threshold
SEVERITY
MINOR
THRESHOLD
5
THROTTLE
0
DATAWORDS
Minor Threshold (MB)–FOUR_BYTES
Current Value (MB)–FOUR_BYTES
PRIMARY
CAUSE
Too many processes are running.
PRIMARY
ACTION
Stop the proliferation of executables (processes-scripts).
SECONDARY
CAUSE
File spaces /tmp or /var/run are over-used.
SECONDARY
ACTION
Cleanup the file systems.