502
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
Setting Value
Function
Description
Ref.
34
Reverse Travel Limit (N.
C.)
If you turn off a terminal while a motor rotates in reverse, the drive turns off the brake release command (holds the
brake), the motor coasts to stop, and the output frequency becomes 0. If you turn off a terminal while a motor
rotates forward, the motor will not stop.
ON : Enables the reverse operation Run command.
OFF : Disables the reverse operation Run command.
35
Impact Stop Enable
When the terminal is ON and the drive receives a stop command while the output frequency is more than the
impact stop creep frequency, the drive decelerates until it is at the set impact stop creep frequency.
ON : Enables the Impact Stop function.
OFF : Cancel the Impact Stop function and turn OFF the brake release command.
36
Light-load Accel 2
Enabled
Enables or disables the selection of Light-Load Accel 2 Enabled function.
ON : Enabled
OFF : Disable
37
Multi-Step Speed
Reference 4
Uses speed references
d1-01 to d1-16
to set a multi-step speed reference.
Note:
On drives with software versions PRG: 01021 and later, this function is enabled.
38
Counterweight Selection
Switch
C4-02 [Torque Compensation Delay Time]
,
E1-08 [Mid Point A Voltage]
and
E1-10 [Minimum Output
Voltage]
. The drive decides parameters based on the combination of the condition of the terminals ON or OFF and
Run command orientation (Forward/Reverse).
39
Motor 3 Selection
Switches motor 1 or motor 2 to motor 3. Switch the motor while the motor is stopped.
ON : Selects motor 3
OFF : Select motor 1 or motor 2 (Select the terminal set to
H1-xx = 16 [Motor 2 Selection]
)
Note:
Set
H1-xx = 16
, when you set
H1-xx = 39
. If you set
H1-xx = 39
, but do not set
H1-xx = 16
, the drive will
detect
oPE03 [Multi-Function Input Setting Err]
.
3A
Micro Speed Gain1
Multiplies the gain set in
S2-16 [Micro Speed Gain1]
by the final step of frequency reference when the terminal is
ON.
3B
Micro Speed Gain2
Multiplies the gain set in
S2-17 [Micro Speed Gain2]
by the final step of frequency reference when the terminal is
ON.
40
Forward RUN (2-Wire)
Input the Forward Run command for 2-wire sequence 1. Use it paired with the
Reverse Run Command (2-Wire
Seq) [H1-xx = 41]
.
ON : Forward Run
OFF : Run Stop
Note:
•
When the both Forward run command and Reverse run command terminals have been turned ON, the drive
detects
EF [FWD/REV Run Command Input Error]
(minor fault), and the motor ramps to stop.
•
The Forward run/Reverse run command is set to terminals S1 and S2 when you initialize the drive for 2-wire
sequence.
41
Reverse RUN (2-Wire)
Input the Reverse run command for 2-wire sequence 1. Use it paired with the
Forward Run Command (2-Wire Seq)
[H1-xx = 40]
.
ON : Reverse Run
OFF : Run Stop
Note:
•
When the both Forward run command and Reverse run command terminals have been turned ON, the drive
detects
EF [FWD/REV Run Command Input Error]
(minor fault), and the motor ramps to stop.
•
The Reverse run command is set to terminal S2 when you initialize the drive for 2-wire sequence.
44
Add Offset Frequency 1
(d7-01)
Sets the function to add the offset frequency set in
d7-01 [Offset Frequency 1]
to the frequency reference when the
terminal activates.
45
Add Offset Frequency 2
(d7-02)
Sets the function to add the offset frequency set in
d7-02 [Offset Frequency 2]
to the frequency reference when the
terminal activates.
46
Add Offset Frequency 3
(d7-03)
Sets the function to add the offset frequency set in
d7-03 [Offset Frequency 3]
to the frequency reference when the
terminal activates.
47
Node Setup (CANopen)
Sets the function in CANopen communications to start the Node Setup function to set the drive node address from
the host controller.
60
DC Injection Braking
Command
Sets the command to use DC Injection Braking to stop the motor.
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...