When Pos Err Reset is enabled by multi-function digital input, the frequency reference of the
drive may change in steps.
・
When the slave is LOCAL mode or for Forward/Reverse Run JOG operations, the frequency
reference is restored to the standard frequency reference and the set acceleration and
deceleration times (C1-01 and C1-02) are used.
3.3
System Configuration
The master encoder signal is input to the PG option card attached to the CN5-B port of the
slave. The slave encoder signal is input to the PG option card attached to the CN5-C port of
the slave.
Figure 3.2 Example of Master and Slave Connections