496
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
F7-19
(03F7)
EtherNet/IP Torque
Scale Factor
Sets the scaling factor for the torque monitor in the EtherNet/IP Class ID 2AH Object.
0
(-15 - +15)
F7-20
(03F8)
EtherNet/IP Power
Scaling Factor
Sets the scaling factor for the power monitor in the EtherNet/IP Class ID 2AH Object.
0
(-15 - +15)
F7-21
(03F9)
EtherNet/IP Voltage
Scale Factor
Sets the scaling factor for the voltage monitor in the EtherNet/IP Class ID 2AH Object.
0
(-15 - +15)
F7-22
(03FA)
EtherNet/IP Time
Scaling
Sets the scaling factor for the time monitor in the EtherNet/IP Class ID 2AH Object.
0
(-15 - +15)
F7-23
(03FB)
Dynamic Out Param 1
for CommCard
When you use an Ethernet/IP option, sets Output Assembly 116. The drive writes the
values from Output Assembly 116 to the MEMOBUS/Modbus address register that is
stored for each parameter. The drive will not write the values from Output Assembly
116 to the registers when the MEMOBUS/Modbus address is 0. When you use a
PROFINET option, set this parameter to set to configurable output 1.
0
F7-24
(03FC)
Dynamic Out Param 2
for CommCard
When you use an Ethernet/IP option, sets Output Assembly 116. The drive writes the
values from Output Assembly 116 to the MEMOBUS/Modbus address register that is
stored for each parameter. The drive will not write the values from Output Assembly
116 to the registers when the MEMOBUS/Modbus address is 0. When you use a
PROFINET option, set this parameter to set to configurable output 2.
0
F7-25
(03FD)
Dynamic Out Param 3
for CommCard
When you use an Ethernet/IP option, sets Output Assembly 116. The drive writes the
values from Output Assembly 116 to the MEMOBUS/Modbus address register that is
stored for each parameter. The drive will not write the values from Output Assembly
116 to the registers when the MEMOBUS/Modbus address is 0. When you use a
PROFINET option, set this parameter to set to configurable output 3.
0
F7-26
(03FE)
Dynamic Out Param 4
for CommCard
Sets Output Assembly 116 when you use an Ethernet/IP option. The drive writes the
values from Output Assembly 116 to the MEMOBUS/Modbus address register that is
stored for each parameter. The drive will not write the values from Output Assembly
116 to the registers when the MEMOBUS/Modbus address is 0. When you use a
ProfiNet option, set this parameter to set to configurable output 4.
0
F7-27
(03FF)
Dynamic Out Param 5
for CommCard
When you use an Ethernet/IP option, sets Output Assembly 116. The drive writes the
values from Output Assembly 116 to the MEMOBUS/Modbus address register that is
stored for each parameter. The drive will not write the values from Output Assembly
116 to the registers when the MEMOBUS/Modbus address is 0. When you use a
PROFINET option, set this parameter to set to configurable output 5.
0
F7-28
(0370)
Dynamic Out Param 6
for CommCard
When you use an Ethernet/IP option, sets Output Assembly 116. The drive writes the
values from Output Assembly 116 to the MEMOBUS/Modbus address register that is
stored for each parameter. The drive will not write the values from Output Assembly
116 to the registers when the MEMOBUS/Modbus address is 0.
0
F7-29
(0371)
Dynamic Out Param 7
for CommCard
When you use an Ethernet/IP option, sets Output Assembly 116. The drive writes the
values from Output Assembly 116 to the MEMOBUS/Modbus address register that is
stored for each parameter. The drive will not write the values from Output Assembly
116 to the registers when the MEMOBUS/Modbus address is 0.
0
F7-30
(0372)
Dynamic Out Param 8
for CommCard
When you use an Ethernet/IP option, sets Output Assembly 116. The drive writes the
values from Output Assembly 116 to the MEMOBUS/Modbus address register that is
stored for each parameter. The drive will not write the values from Output Assembly
116 to the registers when the MEMOBUS/Modbus address is 0.
0
F7-31
(0373)
Dynamic Out Param 9
for CommCard
When you use an Ethernet/IP option, sets Output Assembly 116. The drive writes the
values from Output Assembly 116 to the MEMOBUS/Modbus address register that is
stored for each parameter. The drive will not write the values from Output Assembly
116 to the registers when the MEMOBUS/Modbus address is 0.
0
F7-32
(0374)
Dynamic Out Param 10
for CommCard
When you use an Ethernet/IP option, sets Output Assembly 116. The drive writes the
values from Output Assembly 116 to the MEMOBUS/Modbus address register that is
stored for each parameter. The drive will not write the values from Output Assembly
116 to the registers when the MEMOBUS/Modbus address is 0.
0
F7-33
(0375)
Dynamic In Param 1 for
CommCard
Sets Input Assembly 166 when you use an Ethernet/IP option. The drive sends the
values from the MEMOBUS/Modbus address registers stored for each parameter to
Input Assembly 166. The drive returns the default register value for the option card
when the MEMOBUS/Modbus address is 0 and the value sent to Input Assembly 166 is
not defined. When you use a ProfiNet option, set this parameter to set to configurable
input 1.
0
F7-34
(0376)
Dynamic In Param 2 for
CommCard
Sets Input Assembly 166 when you use an Ethernet/IP option. The drive sends the
values from the MEMOBUS/Modbus address registers stored for each parameter to
Input Assembly 166. The drive returns the default register value for the option card
when the MEMOBUS/Modbus address is 0 and the value sent to Input Assembly 166 is
not defined. When you use a ProfiNet option, set this parameter to set to configurable
input 2.
0
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...