438
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
Model
Rated Current (A)
2 kHz
5 kHz
8 kHz
10 kHz
12.5 kHz
15 kHz
4091
91.0
91.0
91.0
80.6
67.6
54.6
4112
112.0
112.0
91.8
78.4
-
-
4150
150.0
150.0
123.0
105.0
-
-
4180
180.0
180.0
147.6
126.0
-
-
4216
216.0
216.0
177.1
151.2
-
-
4260
260.0
260.0
213.2
182.0
-
-
4304
304.0
304.0
249.3
212.8
-
-
4371
371.0
371.0
304.2
259.7
-
-
4414
389.0
324.8
-
-
-
-
4453
453.0
378.3
-
-
-
-
4605
605.0
505.2
-
-
-
-
◆
Altitude Derating
Install the drive in a location that has an altitude of 1000 m (3281 ft) or lower.
Derate the output current by 1% for each 100 m (328 ft) to install the drive in altitudes between 1000 to 4000 m
(3281 to 13123 ft).
It is not necessary to derate the rated voltage in these conditions:
•
Installing the drive at 2000 m (6562 ft) or lower
•
Installing the drive between 2000 to 4000 m (6562 to 13123 ft) and grounding the neutral point on the power
supply.
If you do not ground the drive with a neutral network, contact Yaskawa or your nearest sales representative.
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...